Manufactured Products
    SV SERIES
      Product Literature
      Model Specifications
      Clearance to Combustibles













SV SERIES: Product Literature
MODEL
NUMBER
GAS TYPE
(circle one)
BTUs TYPICAL
MOUNT
HEIGHT
LENGTH WEIGHT ALLOWABLE
VENT
LENGTH
SV 20-50 N or LP 50,000 10' - 16' 22'-4" 140# 25
SV 20-60 N or LP 60,000  11' - 18' 22'-4" 140# 25
SV 20-75 N or LP 75,000 13' - 20' 22'-4" 140# 30
SV 20-100 N or LP 100,000 15' - 23' 22'-4" 140# 35
SV 30-50 N or LP 50,000 10' - 15' 32'-0" 180# 20
SV 30-60 N or LP 60,000 11' - 16' 32'-0" 180# 20
SV 30-75 N or LP 75,000 12' - 18' 32'-0" 180# 25
SV 30-100 N or LP 100,000 15' - 23' 32'-0" 180# 30
SV 30-125 N or LP 125,000 15' - 25' 32'-0" 180# 35
SV 40-50 N or LP 50,000  10' - 15' 41'-8" 210# 20
SV 40-60 N or LP 60,000 11' - 16' 41'-8" 210# 20
SV 40-75 N or LP 75,000 12' - 18' 41'-8" 210# 25
SV 40-100 N or LP 100,000 13' - 20' 41'-8" 210# 25
SV 40-125 N or LP 125,000 15' - 25' 41'-8" 210# 30
SV 40-150 N or LP 150,000  16' - 30' 41'-8" 210# 35
SV 40-175 N or LP 175,000 17' - 35' 41'-8" 210# 35
SV 50-100 N or LP 100,000 13' - 20' 51'-4" 255# 25
SV 50-125 N or LP 125,000 15' - 25' 51'-4" 255# 30
SV 50-150 N or LP 150,000  16' - 30' 51'-4" 255# 30
SV 50-175 N or LP 175,000 17' - 35' 51'-4" 255# 35
SV 50-200 N or LP 200,000 18' - 40' 51'-4" 255# 35
SV 60-125 N or LP 125,000 15' - 25' 61'-0" 285# 25
SV 60-150 N or LP 150,000 16' - 30' 61'-0" 285# 25
SV 60-175 N or LP 175,000 17' - 35' 61'-0" 285# 30
SV 60-200 N or LP 200,000 18' - 40' 61'-0" 285# 30
SV 60-225 N or LP 225,000 20' - 42' 61'-0" 285# 35
SV 70-175 N or LP 175,000 17' - 35' 70'-8" 320# 25
SV 70-200 N or LP 200,000 18' - 40' 70'-8" 320# 30
SV 70-225 N or LP 225,000 20' - 42' 70-8" 320# 35
SV 80-200 N or LP 200,000 18' - 40' 80'-4" 350# 25
SV 80-225 N or LP 225,000 20' - 42' 80'-4" 350# 30
"For energy conservation...
the natural alternative."
Brant Radiant Heaters Limited
34 Scott Avenue · Post Office Box 395
Paris ·Ontario · Canada · N3L 3T5
Telephone (519) 442-7823 · Fax (519) 442-7321